CCU activation
Kone · CMXC-022 Frequency Control Upgrade Kit
What does 93 mean?
A Controlled Common Use (CCU) activation has occurred, meaning another device connected to the CAN bus initiated the stopping of the R&M Materials Handling Frequency Converter system. This indicates an external device commanding a stop via the shared network.
Common Causes
- Another device connected to the CAN bus has caused the system to stop
Repair Steps & Checklist
Click steps to track your progress.
- 1
Verify the operational status and control logic of other devices connected to the CAN bus to identify which device is initiating the CCU stop command.
- 2
Inspect the CAN bus wiring and connections (e.g., termination resistors, shielding) for damage, loose connections, or incorrect configuration.
- 3
Verify the frequency converter's communication parameters (e.g., CAN bus address, baud rate, control source selection) are correctly configured according to the system's design documentation.
- 4
Check the status of any external safety circuits or control logic (e.g., emergency stops, interlocks) that are configured to issue a stop command via the CAN bus.