36

36 Battery Drain Alarm

Kone · Elevator Control

What does 36 mean?

An alarm indicating excessive battery drain has been triggered, suggesting a higher than normal current draw. This condition limits the drive speed.

Common Causes

  • High current draw from the battery, possibly due to an electrical load or system inefficiency.
  • Internal fault in a connected electrical component causing parasitic drain.
  • Aging battery with reduced capacity and increased internal resistance.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Measure the battery terminal voltage under no-load conditions and compare it to the specified nominal voltage.

  2. 2

    Inspect all battery cables and connections for corrosion, looseness, or physical damage.

  3. 3

    Verify the battery charger's output voltage and current when connected to the battery to ensure proper charging function.

  4. 4

    Check the battery's manufacturing date and last replacement record to assess its expected lifespan.

  5. 5

    Monitor the total current draw from the battery during both standby and operational states to identify any excessive or unexpected loads.