55

55 Lift Down Coil Fault

Kone · Elevator Control

What does 55 mean?

A fault has been detected in the lift down coil, indicating an electrical issue with the solenoid responsible for lowering the platform. This disables both lifting and driving functions.

Common Causes

  • Lift down coil open circuit, short circuit, or high resistance.
  • Damaged wiring or loose connections to the lift down coil.
  • Control circuit failure attempting to activate the coil.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the nominal supply voltage at the terminals connected to the lift down solenoid coil.

  2. 2

    Inspect the wiring harness and connectors leading to the lift down solenoid coil for any visible damage, chafing, or loose connections.

  3. 3

    Measure the resistance of the lift down solenoid coil (with power disconnected) and compare it against the specified value in the Kone Kone service manual.

  4. 4

    Check the output status and voltage from the Kone Kone Elevator Control unit's relevant output terminal to ensure it is commanding the lift down solenoid correctly.

  5. 5

    Inspect the mechanical plunger and linkage of the lift down solenoid for free movement and any obstructions that could prevent its proper operation.

Browse all codes in this manual (60)
Verified technical data. Last updated: March 2026