99

Platform Load is over 99%

Kone · Elevator Control

What does 99 mean?

The detected load on the platform exceeds 99% of its rated capacity. This is a warning only, indicating the platform is at its absolute load limit.

Common Causes

  • Platform loaded at or near its maximum capacity.
  • Malfunction of the platform overload sensor, providing an inaccurate reading.
  • Minor fluctuations in load pushing it over the 99% threshold.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the actual load on the elevator platform against its rated capacity.

  2. 2

    Inspect all wiring and connections for the load weighing system sensors (e.g., load cells) for damage, corrosion, or looseness.

  3. 3

    Check the elevator control system parameters related to load weighing, capacity settings, and calibration values for correct configuration according to manufacturer documentation.

  4. 4

    Verify the physical mounting and integrity of the load weighing sensors to ensure no obstructions or mechanical stress are affecting their measurement.

  5. 5

    Perform a functional test or recalibration of the load weighing system using known weights if the above steps do not resolve the issue, following manufacturer procedures.

Browse all codes in this manual (60)
Verified technical data. Last updated: March 2026