71

CCr-Trip

Kuka · KR C2 Robot Controller

What does 71 mean?

This fault signifies a crash of the internal microcontroller for either the KPS-600 or KSD device. This is a severe error indicating an unexpected software or hardware failure within the control unit, leading to a loss of control and operation.

Repair Steps

  1. 1

    Perform a power cycle of the device to attempt a software reset.

  2. 2

    Check for any external electrical noise or interference on control signals connected to the device.

  3. 3

    Verify the integrity and version of the device firmware for potential updates or corruption.

Browse all codes in this manual (54)
Verified technical data. Last updated: March 2026