HEAT SINK TEMPERATURE Ax
Axis Heat Sink Overtemperature
Kuka · KR C2 Robot Controller
What does HEAT SINK TEMPERATURE Ax mean?
An overtemperature condition has been detected on the heat sink of the servo drive module for the specified axis (Ax). This indicates inadequate cooling or excessive load on the axis.
Repair Steps
- 1
Check the cabinet cooling circuit and fans for proper operation and airflow.
- 2
Reduce the load on the affected axis by decreasing the Override (OVR) setting in the robot program.
- 3
Reduce the velocity for the affected axis using the `$VEL_AXIS` parameter.
- 4
Reduce the acceleration for the affected axis using the `$ACC_AXIS` parameter.
Verified technical data. Last updated: March 2026
Source: Kuka KR C2 Robot Controller