26032
IxT overload error, KPP/KSP (axis)
Kuka · KR C4 extended
What does 26032 mean?
The axis is overloaded, indicated by the IxT (Current x Time) monitoring function. This fault suggests that the mean continuous current is too high, potentially leading to overheating and damage to the motor or drive.
Common Causes
- Excessive load in the program during start-up or operation.
- Modifications made to the system (e.g., increased payload, changed mechanics).
- Temperature influences (e.g., high ambient temperature).
- CBS pressure issue.
- Gear unit fault.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Review robot program to identify and reduce excessive load.
- 2
Reinitialize the drive bus: Power Off / Power On.
- 3
Check machine for mechanical issues or resistance.
- 4
Check trace recording of axis current.
- 5
Adapt program velocity to reduce continuous load.
- 6
Check CBS pressure.
Verified technical data. Last updated: March 2026
Related Faults
Source: Kuka KR C4 extended