26024
Max. following error exceeded ({Drive})
Kuka · KSS 8.3 Operating & Programming Manual
What does 26024 mean?
The deviation between the commanded position and the actual position for the specified drive ({Drive}) has exceeded the maximum allowable limit. This often occurs in torque mode operations if regular monitoring functions are not appropriately deactivated, or due to external mechanical resistance.
Common Causes
- Excessive deviation between commanded and actual position for the specified drive ({Drive})
- Regular monitoring functions remaining active during torque mode operations when they should be deactivated
- Mechanical load or obstruction on the specified drive ({Drive}) preventing accurate positioning
Repair Steps & Checklist
Click steps to track your progress.
- 1
If torque mode is intentionally active, verify that regular monitoring functions are deactivated using SET_TORQUE_LIMITS(..., monitor #off)
- 2
Investigate mechanical load or obstruction on the specified drive ({Drive}) that might be causing position deviation
- 3
Check for correct tuning of the drive's position control loop
Verified technical data. Last updated: March 2026
Related Faults
Source: KUKA KSS 8.3 Operating & Programming Manual