SnsrCableError

Sensor cable interrupted!

Kuka · LaserTech 3.1

What does SnsrCableError mean?

The connection to a sensor has been interrupted, indicating a physical break or disconnection in the sensor cable. This prevents data transmission from the sensor, leading to a loss of monitoring.

Repair Steps

  1. 1

    Physically inspect the sensor cable along its entire length for damage, cuts, or disconnections.

  2. 2

    Verify cable terminations at both the sensor and the controller for secure connections.

  3. 3

    Initiate a program reset command to clear the error state.

Browse all codes in this manual (46)
Verified technical data. Last updated: March 2026