ce6

CAN Module Warning/Bus-Off

Lenze · 8200 Vector Drive

What does ce6 mean?

The CAN function module on the FIF has reported a 'Warning' or 'Bus-Off' status, indicating underlying communication issues. This often points to problems with bus termination, cable shielding, PE connection, or an overloaded bus. While 'Warning' might allow limited operation, 'Bus-Off' will completely halt communication.

Complete Troubleshooting Guide

  1. 1

    Verify that the CAN bus termination resistors are correctly installed and configured.

  2. 2

    Check the shield connection of all CAN bus cables for proper grounding and integrity.

  3. 3

    Ensure the protective earth (PE) connection for the controller and bus components is secure.

  4. 4

    Assess the bus load and, if necessary, reduce the baud rate to improve communication reliability.