EEr
External Fault (TRIP-SET)
Lenze · 8200 Vector Drive
What does EEr mean?
An external disturbance has been detected, activating a digital signal assigned to the TRIP-SET function (DCTRL1-TRIP-SET). This typically results from a LOW level at the signal source for this function, causing the controller to inhibit. Ignoring this can lead to system shutdown and operational delays.
Complete Troubleshooting Guide
- 1
Identify and rectify the external disturbance that triggered the DCTRL1-TRIP-SET signal.
- 2
Verify the external sensor or encoder connected to the TRIP-SET input.
- 3
Ensure the digital signal source assigned to DCTRL1-TRIP-SET is returning to a HIGH level after the disturbance is cleared.
- 4
Reset the fault using DCTRL1-TRIP-RESET or other available reset options once the cause is resolved.