0075

PR0 (Error in parameter set)

Lenze · 9300 Series

What does 0075 mean?

An error has occurred in the parameter set, possibly due to an operating system software update. The Lenze default settings (C0003 = 1) are automatically loaded as a result of this fault.

Common Causes

  • Corruption of the stored parameter set in non-volatile memory (EEPROM) due to power fluctuations.
  • Incomplete or interrupted parameter download from a higher-level controller or PC software (e.g., Engineer).
  • Incompatibility of a saved parameter set with the current firmware version after an update.
  • Attempting to restore a parameter set from a different hardware variant or controller model.
  • Internal memory error preventing proper loading or saving of parameters.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Cycle power to the drive and check if the fault clears and the default parameters (C0003 = 1) are active.

  2. 2

    Verify the current firmware version (C0004) and ensure any loaded parameter set is compatible with it.

  3. 3

    Reload the last known good parameter set from a backup file using the drive's configuration software (e.g., "Lenze Engineer").

  4. 4

    Manually re-enter critical application parameters (e.g., motor data, speed limits) and save them to non-volatile memory (e.g., by setting C0003 = 2).

  5. 5

    If the fault recurs with new parameters, inspect the drive's internal memory health via diagnostic parameters if available (refer to manual for specific memory status indicators).

Browse all codes in this manual (145)
Verified technical data. Last updated: March 2026

Related Faults