0105

H05 (Internal fault (memory))

Lenze · 9300 Series

What does 0105 mean?

An internal fault related to the controller's memory has been detected. This indicates a critical hardware or firmware issue within the drive itself.

Common Causes

  • Defective internal RAM (Random Access Memory) causing instruction or data corruption during operation.
  • Corrupted non-volatile memory (e.g., EEPROM, Flash) where firmware or parameters are stored.
  • Internal bus communication error between the CPU and memory modules.
  • Firmware bug or heap overflow leading to memory access violations.
  • Aging or thermal stress leading to premature failure of memory ICs.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Perform a power cycle (turn off, wait 30 seconds, turn on) to the drive to attempt a memory reinitialization.

  2. 2

    Reset the drive to factory default settings (C0003 = 1) to clear any potentially corrupted parameter sets in memory.

  3. 3

    Attempt to re-upload the latest stable firmware version for the drive using the manufacturer's specified tool.

  4. 4

    Check the drive's internal diagnostic logs (if accessible via software) for specific memory addresses or error codes.

  5. 5

    If the fault persists after firmware update and resets, the internal memory hardware is likely compromised, requiring drive replacement.

Browse all codes in this manual (145)
Verified technical data. Last updated: March 2026

Related Faults