OC1 Overcurrent in motor cable
Lenze · 9300 Servo Controller
What does 0011 mean?
An overcurrent (Ia > 2.25 x IN) has occurred in the motor cable, detected by hardware monitoring. This can be caused by a short circuit in the motor cable, excessive capacitive charging current of the motor cable, or acceleration/deceleration times that are too short for the load. It can also indicate a missing mains phase or an encoder wiring issue.
Additional Steps
Steps 1–2 are listed in Priority Fix.
- 3
Increase the gain (P component) of the Imax controller (C0075).
- 4
Reduce the integral-action time (integral action component) of the Imax controller (C0076).
- 5
If the drive is connected to a coasting machine, activate the flying restart circuit.
- 6
If an encoder error is suspected, check the wiring of the encoder, especially verifying that tracks during encoder feedback of motor speed are not interchanged.