E.OP1

Communication option fault

Mitsubishi Electric · FR E700

What does E.OP1 mean?

This communication option fault stops the inverter output due to a communication line error during CC-Link operation. It can be caused by physical cable issues, incorrect lengths, or improper termination. This disruption prevents control and monitoring via the CC-Link network.

Complete Troubleshooting Guide

  1. 1

    Check the inverter's LED display for any fault indications and apply corresponding countermeasures as per the manual.

  2. 2

    Inspect the CC-Link dedicated cable for breaks, damage, or improper connections.

  3. 3

    Verify that the CC-Link dedicated cables between stations are within their specified length limits (refer to the CC-Link master module manual).

  4. 4

    Ensure the built-in terminating resistor of the end station is turned ON, or that the one-touch connector plug with a terminating resistor is securely attached.