Analog input fault
Analog Input Fault
Mitsubishi Electric · FR-D700 Basic Inverter
What does Analog input fault mean?
A voltage (or current) has been incorrectly applied to terminal 4 due to a mismatch between the Pr. 267 Terminal 4 input selection setting and the physical voltage/current input switch position. This incorrect configuration can lead to erroneous frequency commands, inaccurate control, or potential damage to the inverter's analog input circuitry.
Complete Troubleshooting Guide
- 1
If intending to use current input, ensure the voltage/current input switch is set to the 'I' position and provide a current frequency command.
- 2
If intending to use voltage input, set Pr. 267 Terminal 4 input selection accordingly and ensure the voltage/current input switch is set to the 'V' position.