E.1 to E.3

Option fault

Mitsubishi Electric · A500 Inverter

What does E.1 to E.3 mean?

The inverter output is stopped if a contact fault occurs at the connector between the inverter and a communication option, or if there is a fault of the communication option itself. The numbers 1 to 3 indicate the specific option slot numbers where the fault is detected.

Repair Steps

  1. 1

    Verify that the communication option for slot 1, 2, or 3 is plugged into its respective connector securely.

Browse all codes in this manual (21)
Verified technical data. Last updated: March 2026
Source: Mitsubishi Electric A500 Inverter