Ud

Overheat protection (Outdoor pipe thermistor)

Mitsubishi Electric · PUZ-HA30/36NHA4 Outdoor Unit

What does Ud mean?

This fault triggers if the outdoor pipe thermistor (TH1) detects 70°C (158°F) or more during compressor operation. It indicates excessive heat within the outdoor unit, likely due to restricted airflow, a malfunctioning outdoor fan, or a faulty thermistor. Persistent overheating can lead to compressor failure and significant reduction in cooling efficiency.

Repair Steps

  1. 1

    Inspect the outdoor unit's air passage for any obstructions, dirt, or debris.

  2. 2

    Verify proper operation of the outdoor fan motor and fan blades.

  3. 3

    Check the outdoor pipe thermistor (TH1) for correct resistance values and secure connections.

  4. 4

    Turn the unit off and on again. If the error code reappears, address the root cause, possibly replacing the thermistor if it's faulty.

Browse all codes in this manual (30)
Verified technical data. Last updated: March 2026
Source: Mitsubishi Electric PUZ-HA30/36NHA4 Outdoor Unit
Mitsubishi Electric Error Ud: Overheat protection (Outdoor pipe thermistor) — Troubleshooting Guide | ErrorLib