E49

Low Pressure Fault / Low Voltage Detected

Mitsubishi Electric · R410A Systems

What does E49 mean?

The system has detected either a low refrigerant pressure condition or a low voltage condition. Low pressure often indicates insufficient refrigerant charge, while low voltage points to power supply issues to the outdoor unit.

Repair Steps

  1. 1

    Measure system low-side pressure using manifold gauges — perform leak detection and recharge if low.

  2. 2

    Measure incoming AC line voltage at the outdoor unit's main power terminals — compare to nameplate requirements.

  3. 3

    Check for loose power connections at the outdoor unit's main terminal block and internal wiring.

Browse all codes in this manual (60)