P2
Pipe Sensor Abnormal
Mitsubishi Electric · R410A Systems
What does P2 mean?
The indoor coil pipe sensor is abnormal, indicating an open circuit, short circuit, or incorrect resistance. This prevents accurate refrigerant temperature monitoring, which is critical for defrost logic and coil protection.
Repair Steps
- 1
Measure the resistance of the pipe sensor at its leads — compare to a resistance-temperature chart if available.
- 2
Inspect the sensor's wiring and connector on the indoor unit PCB for damage, corrosion, or secure seating.
- 3
Verify the sensor is securely attached to the refrigerant pipe for proper thermal contact.
Verified technical data. Last updated: March 2026
Source: Mitsubishi Electric R410A Systems