Output current detection value exceeded

Output Current Detection Value Exceeded

Mitsubishi · FR-D700 Inverter (Basic)

What does Output current detection value exceeded mean?

The output current has exceeded the detection level set in a parameter. This functions as a protective measure to prevent overcurrent conditions that could damage the motor or the inverter's power components. Incorrect parameter settings can trigger this unnecessarily, or it could indicate an actual motor overload or short circuit condition.

Complete Troubleshooting Guide

  1. 1

    Check and adjust the setting of Pr. 150 Output current detection level to match your application's requirements.

  2. 2

    Review Pr. 151 Output current detection signal delay time, Pr. 166 Output current detection signal retention time, and Pr. 167 Output current detection operation selection for appropriate configuration.

  3. 3

    Investigate the motor and load for potential overload conditions or mechanical issues that could cause excessive current.