E.OP1

Communication Option Fault

Mitsubishi · FR-E800 Variable Frequency Drive

What does E.OP1 mean?

The inverter output is shut off due to a communication line error in the installed communication option. This can stem from incorrect option settings, a loose plug-in option card, or a damaged communication cable, including improper termination. Loss of communication functionality can disrupt system control.

Complete Troubleshooting Guide

  1. 1

    Verify the option function settings and operation in the inverter parameters.

  2. 2

    Ensure the plug-in option card is firmly seated in its connector.

  3. 3

    Inspect the communication cable for any breaks or damage and confirm that the terminating resistor (if required) is correctly installed.

  4. 4

    If the fault recurs after resetting the inverter, contact your sales representative.