E.SOT
Motor Step Out
Mitsubishi · FR-E800 Variable Frequency Drive
What does E.SOT mean?
The inverter output is shut off when the motor loses synchronization during operation, a condition specifically monitored under PM sensorless vector control. This fault indicates a loss of control over the motor's rotor position, leading to erratic operation.
Complete Troubleshooting Guide
- 1
Increase the acceleration time parameter to allow for smoother motor starts.
- 2
Reduce the mechanical load on the PM motor.
- 3
If restarting during coasting, set Pr.57 (Restart coasting time) to a value other than '9999' and enable automatic restart after instantaneous power failure.
- 4
Verify the physical connections of the IPM motor.
- 5
Perform offline auto tuning for the PM motor to correctly identify its characteristics.