4-time blink 2.5-second OFF
Indoor Control System Memory Error
Mitsubishi · MSZ-FH06-18NA Heat Pump System
What does 4-time blink 2.5-second OFF mean?
This fault occurs when the indoor electronic control P.C. board cannot properly read data from its nonvolatile memory. It indicates a critical issue with the board's internal memory, which prevents the unit from retaining settings or executing operational commands. Without a functioning control board, the indoor unit will remain inoperable.
Additional Steps
Steps 1–2 are listed in Priority Fix.
- 3
Ensure all connectors attached to the P.C. board are securely seated and free from loose contacts.
- 4
If the fault persists after these checks, the indoor electronic control P.C. board must be replaced.
Source: Mitsubishi MSZ-FH06-18NA Heat Pump System