U7
Too Low Superheat Due to Low Discharge Temperature
Mitsubishi Electric · Mitsubishi PUZ-HA30-36NHA4 Outdoor Unit
What does U7 mean?
The system continuously detects discharge superheat less than or equal to -15°C [5°F] for 3 minutes, even with the linear expansion valve (LEV) at its minimum open pulse and the compressor running for 10 minutes. This indicates potential liquid floodback to the compressor, posing a significant risk of compressor damage.
Additional Steps
Steps 1–2 are listed in Priority Fix.
- 3
Check the coil of the linear expansion valve for disconnection or loose connections.
- 4
Check the connection and contact of the LEV-A and LEV-B connectors on the outdoor controller circuit board.
- 5
Check the linear expansion valve for proper operation, referring to section 10-6 for diagnostic procedures.
Source: Mitsubishi PUZ-HA30-36NHA4 Outdoor Unit
Open Manual (Page 27)