Oversetter...
ERR_CONN_REJECTED
Incoming Connection is rejected by the IP address validation
Allen-Bradley · MicroLogix 1400 Programmable Controllers
Hva betyr ERR_CONN_REJECTED ?
An incoming Modbus TCP connection attempt was rejected because its source IP address did not pass the controller's configured IP address validation rules. This is a security feature to control access.
Vanlige årsaker
- The source IP address of the client is not in the allowed list configured on the Modbus TCP server.
- IP address validation is enabled and the client's IP is explicitly denied or not whitelisted.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Review the Modbus TCP server's IP address validation settings in the controller configuration.
- 2
Add the client's IP address to the allowed list if it is a legitimate connection.
- 3
Temporarily disable IP address validation if it's not required for security, but exercise caution.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: Allen-Bradley MicroLogix 1400 Programmable Controllers