NTE_BAD_SIGNATURE

Invalid Import File Signature

Beckhoff · TwinCAT 2 Automation Interface

Hva betyr NTE_BAD_SIGNATURE ?

The file specified for import does not contain a valid tree item or has a corrupted signature (0x80090006). This error occurs when ImportChild() attempts to read the file but determines its content is not a recognized TwinCAT tree item export format.

Vanlige årsaker

  • The signature of the import or firmware file is invalid or corrupted.
  • The file has been tampered with, and its integrity check failed.
  • The checksum of the imported data does not match the expected value.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Ensure the bstrFile was generated by ExportChild() from a valid TwinCAT tree item.

  2. 2

    Attempt to open the export file (.tce) with a text editor to check for obvious corruption or non-XML content.

  3. 3

    Regenerate the export file from the source TwinCAT configuration if possible, ensuring a valid export process.

Se alle koder i denne manualen (12)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Beckhoff TwinCAT 2 Automation Interface