TSM_E_CORRUPTEDLINK

Corrupted Variable Link

Beckhoff · TwinCAT 2 Automation Interface

Hva betyr TSM_E_CORRUPTEDLINK ?

The specified variables cannot be unlinked, possibly due to a corrupted or invalid link definition in the TwinCAT configuration (0x98510005). This indicates an issue with the integrity of the variable linkage data within the system.

Vanlige årsaker

  • The link to a PLC variable or an external data source is broken.
  • A pointer in the control logic is corrupted or points to invalid memory.
  • Network communication issues have disrupted the data link.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Verify the bstrV1 and bstrV2 path names accurately identify the linked variables.

  2. 2

    Attempt to manually unlink the variables using the TwinCAT System Manager to diagnose the issue.

  3. 3

    If the link appears valid, consider recreating the configuration section containing these variables or the entire project if widespread corruption is suspected.