SP0002

Excessive Velocity Error

Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters

Hva betyr SP0002 ?

The spindle motor's actual velocity deviated excessively from the commanded velocity. This can be caused by mechanical load, incorrect tuning, or encoder issues.

Vanlige årsaker

  • Insufficient torque from the spindle amplifier to meet commanded speed.
  • Mechanical load changes exceeding amplifier capacity.
  • Encoder feedback signal noise or loss of signal.
  • Tuning parameters for velocity control (e.g., P1-02, P1-03) are suboptimal.
  • Spindle encoder resolution mismatch with amplifier settings.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Inspect the encoder feedback cable for damage and ensure secure connections.

  2. 2

    Verify that velocity feedback parameters (e.g., P1-02, P1-03) are appropriately tuned.

  3. 3

    Measure the output voltage of the spindle amplifier during acceleration.

  4. 4

    Check for any mechanical issues on the driven spindle or gearbox.

  5. 5

    Confirm the encoder resolution matches the value configured in P1-06.