Oversetter...
SP0012
DC Link Overcurrent / IPM Alarm
Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters
Hva betyr SP0012 ?
An overcurrent condition is detected in the DC link of the converter, or an alarm is issued by the IPM (Intelligent Power Module). This usually indicates a short circuit in the motor, power module failure, or sudden high load.
Vanlige årsaker
- Short circuit in the motor or motor cabling.
- Faulty IPM (Intelligent Power Module) in the spindle amplifier.
- DC link capacitor failure.
- Overload condition causing excessive current draw.
- Ground fault in the motor or power leads.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Measure the resistance between motor phases (U, V, W) and ground.
- 2
Inspect the spindle motor power cables for signs of damage or insulation breakdown.
- 3
Check the DC link voltage (P+, P-) for stability under load.
- 4
Verify that the braking resistor circuit is functioning correctly.
- 5
Run a low-speed motor test while monitoring DC link current.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: Fanuc AC Spindle Motor Alpha i-Beta i Series Parameters