SP0029
Short-Time Overload
Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters
Hva betyr SP0029 ?
The spindle motor has experienced a short-duration overload condition, exceeding its temporary torque limits. This can occur during heavy cutting or rapid acceleration/deceleration.
Vanlige årsaker
- Spindle motor is commanded to produce torque beyond its momentary rating.
- Rapid acceleration or deceleration commands are too aggressive.
- Machine load suddenly increases beyond expected levels.
- Parameter P2-14 (Short time overload limit) is set too low.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Review programmed feed rates and spindle speeds for sudden changes.
- 2
Measure motor torque output or current draw (P5-04) during transient load.
- 3
Adjust P2-14 parameter to a more suitable value for the application.
- 4
Examine machine operation for unexpected mechanical binding.
Verifisert teknisk data. Sist oppdatert: March 2026