SP0031
Motor Lock Alarm
Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters
Hva betyr SP0031 ?
The spindle motor is detected to be in a locked or stalled condition, preventing rotation. This can be due to excessive mechanical load, a brake issue, or a fault in the motor itself.
Vanlige årsaker
- Spindle motor is mechanically jammed or seized.
- Excessive cutting forces are preventing rotation.
- Amplifier command signal is not reaching the motor.
- Low voltage supply to the motor windings.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Manually rotate spindle shaft to check for free movement.
- 2
Measure motor terminal voltages (U, V, W) when commanded to run.
- 3
Inspect spindle bearing for seizure or damage.
- 4
Verify amplifier output stage is functional (e.g., by checking for abnormal heat).