SP0220
Serial Spindle Amplifier Disconnected (15i)
Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters
Hva betyr SP0220 ?
The cable connected to the serial spindle amplifier for Series 15i is disconnected, or no serial spindle amplifier is connected. This prevents communication and control of the spindle.
Vanlige årsaker
- Serial spindle amplifier disconnected or not communicating (15i).
- Loss of communication with the spindle drive.
- Spindle amplifier not powered or faulty.
- Wiring problem on the serial communication link to the spindle amplifier.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify the serial communication cable connection between the CNC and the spindle amplifier.
- 2
Confirm that a serial spindle amplifier is physically connected to the system for Series 15i.
Verifisert teknisk data. Sist oppdatert: March 2026