Oversetter...
A

PSM External Cooling Fin Fan Stop

Fanuc · Series 30i CNC

Hva betyr A ?

This alarm indicates that a cooling fan associated with the external cooling fin of the Power Supply Module (PSM) has stopped. This failure impairs the module's ability to dissipate heat effectively, risking overheating of power components if not resolved promptly. It can also be triggered by internal connection issues.

Vanlige årsaker

  • Cooling fan of the external cooling fin is broken or jammed.
  • Poor installation of the control printed-circuit board, causing loose connectors between the control and power printed-circuit boards.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check whether the cooling fan of the external cooling fin rotates normally.

  2. 2

    Replace the cooling fan of the external cooling fin if it is not functioning.

  3. 3

    Ensure the control printed-circuit board is securely installed, verifying all connectors between it and the power printed-circuit board are tight.

Se alle koder i denne manualen (20)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder