Heidenhain · NC Control

Hva betyr 2203 F200 ?

The ZN amplitude of the encoder (ERN 1381) for the displayed axis is too small. This indicates a problem with the encoder signal integrity, potentially leading to inaccurate position feedback.

Vanlige årsaker

  • ZN amplitude of the encoder (ERN 1381) for the displayed axis is too small.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check the motor encoder (ERN 1381) cabling for the specified axis, including shielding and ground connections, for damage, loose contacts, or interference.

  2. 2

    Inspect the encoder itself for signs of physical damage, contamination (e.g., oil, dust), or mounting issues that could affect signal generation.

  3. 3

    Verify the power supply voltage to the encoder is present and stable, within the specified operating range.

  4. 4

    If possible, use an oscilloscope to measure the ZN signal amplitude directly at the encoder output and at the control input to detect signal degradation.

Se alle koder i denne manualen (58)
Verifisert teknisk data. Sist oppdatert: March 2026