Motor %.1s: temperature too high
Heidenhain · NC Control
Hva betyr 2205 F230 ?
The temperature of the motor for the displayed axis is too high. This indicates an overheating condition which can lead to motor damage and reduced lifespan.
Vanlige årsaker
- Motor temperature for the displayed axis is too high.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Allow the motor to cool down. Check the motor cooling fan for proper operation and ensure cooling fins are free of dust or obstructions.
- 2
Inspect the mechanical load on the axis for any binding, excessive friction, or misalignment that could cause the motor to overwork.
- 3
Verify the motor's rated current and overload parameters in the NC control to ensure they are correctly set and not allowing prolonged overcurrent.
- 4
Check the motor temperature sensor and its wiring for proper connection, integrity, and functionality.
- 5
Monitor motor current during operation to detect sustained overloads or transient peaks.