2878 A100

Standstill monitoring %.2s

Heidenhain · NC Control

Hva betyr 2878 A100 ?

The rotational speed limit for Safe Controlled Stop (SBH) was exceeded. This occurred while the protective door was open and the key switch was turned to 'automatic,' indicating a safety violation.

Vanlige årsaker

  • Rotational speed limit SBH was exceeded.
  • Protective door was open.
  • Key switch was in 'automatic' mode.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Ensure all protective doors are fully closed and their interlock switches are correctly engaged before operating in 'automatic' mode or at any speed.

  2. 2

    Verify the function and wiring of the safety key switch, ensuring it correctly registers its position and transitions between operating modes.

  3. 3

    Check the SBH (Safe Controlled Stop) speed monitoring parameters to ensure they are configured correctly for the machine's safety requirements.

  4. 4

    Inspect the axis encoder feedback system for accurate speed measurement, as erroneous feedback could falsely trigger this fault.

Se alle koder i denne manualen (58)
Verifisert teknisk data. Sist oppdatert: March 2026