5646 E013

Error in CC switch-off test

Heidenhain · NC Control

Hva betyr 5646 E013 ?

During a CC switch-off test, the CC switch-off signal '-N0' failed to switch to a high (inactive) level. This indicates a hardware defect on the controller board.

Vanlige årsaker

  • CC switch-off signal: -N0 does not switch to high level.
  • Hardware defective.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Power cycle the NC control to attempt a reset of the safety circuit and signal states, then re-attempt the CC switch-off test.

  2. 2

    Check the wiring and connections related to the -N0 signal path on the controller board for any damage, loose terminals, or corrosion.

  3. 3

    Inspect the controller board for any visible damage, burnt components, or signs of malfunction.

  4. 4

    If available, use a multimeter or oscilloscope to monitor the -N0 signal level during the switch-off test to confirm if it remains low when expected to go high.

Se alle koder i denne manualen (58)