2035
Grid volt. Imbalance
Huawei · SUN2000-(3KTL-10KTL)-M1 Solar Inverter
Hva betyr 2035 ?
The difference between grid phase voltages exceeds the upper threshold. This indicates an imbalance in the three-phase power grid, which can affect the inverter's stable operation.
Vanlige årsaker
- The difference between grid phase voltages exceeds the upper threshold.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Monitor if the alarm occurs occasionally, indicating a temporary power grid abnormality. The SUN2000 automatically recovers when the grid stabilizes.
- 2
If the alarm persists, check whether the power grid voltage is within the acceptable range. If not, contact the local power operator.
- 3
If the alarm lasts for a long time, check the AC output power cable connection.