2031

Power grid phase wire short-circuit to PE

Huawei · SUN2000 Solar Inverter

Hva betyr 2031 ?

The impedance of the inverter's output phase wire is low, or it is short-circuited to the Protective Earth (PE) conductor. This fault indicates a ground fault in the AC output wiring, posing safety risks and preventing grid-tied operation.

Vanlige årsaker

  • The impedance of the output phase wire is low.
  • The output phase wire is short-circuited to PE.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check the impedance of the output phase wire to PE.

  2. 2

    Locate the position with lower impedance and restore that.

Se alle koder i denne manualen (33)