2062
Low Insulation Resistance
Huawei · SUN2000 Solar Inverter
Hva betyr 2062 ?
PV arrays are short-circuited with PE, or the ambient air around the PV array is damp, leading to poor insulation between the PV array and the ground. This presents a safety risk and can hinder inverter operation.
Vanlige årsaker
- PV arrays are short-circuited with PE.
- The ambient air of the PV array is damp and the insulation between the PV array and the ground is poor.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check the output resistance of the PV array to ground. If there is a short circuit or lack of insulation, rectify it.
- 2
Check that the PE cable of the SUN2000 is correctly connected.
- 3
If you are sure that the impedance is less than the default value in a cloudy or rainy environment, log in to the mobile phone app, SmartLogger, or NMS and reset the insulation impedance protection threshold.