Safety Circuit Breaks off
Kone · Frequency Inverter
Hva betyr 32 ?
This fault indicates that the critical safety circuit of the lift has been interrupted or opened while the lift was in service. This is a protective measure to immediately halt lift operation when a safety condition is violated.
Vanlige årsaker
- Activation of an emergency stop button in the car or on a landing.
- Opening of car door or landing door interlocks during travel.
- Activation of a safety limit switch, such as pit stop switch or overtravel limits.
- Physical break or poor connection in the safety circuit wiring.
- Malfunction of a safety component (e.g., safety relay, governor switch).
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Inspect all emergency stop buttons in the car and on all landings for activation.
- 2
Verify the closed state of all car door and landing door safety interlocks.
- 3
Check the position and state of all safety limit switches (e.g., pit switch, final limits).
- 4
Perform a continuity test on the entire safety circuit chain to identify any open points.
- 5
Examine the safety relays on the master control board for proper operation and contact closure.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: Kone Frequency Inverter