Oversetter...
26045
Hardware fault, KPP/KSP (axis)
Kuka · KR C4 Operating Instructions
Hva betyr 26045 ?
The KPP or KSP device has detected an internal hardware fault. This indicates a critical issue within the device's internal electronics that requires direct attention to the component itself.
Vanlige årsaker
- Hardware malfunction detected in the KPP/KSP drive or associated control module.
- Encoder failure or signal loss for the axis.
- Motor driver fault within the KPP/KSP unit.
- Over-temperature condition within the KPP/KSP hardware.
- Internal communication error on the KPP/KSP bus.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Reinitialize the drive bus by performing a Power Off / Power On cycle of the entire system.
- 2
Check the specific KPP/KSP device's LEDs for further diagnostic information or specific fault indicators.
- 3
Exchange the defective KPP/KSP device, as the fault is internal hardware-related.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: Kuka KR C4 Operating Instructions