26046
Mains phase failure, KPP/KSP (axis)
Kuka · KR C4 Operating Instructions
Hva betyr 26046 ?
One or more mains phases supplying the KPP/KSP device have failed. This suggests an issue with the incoming AC power supply to the drive, potentially leading to incorrect operation or shutdown.
Vanlige årsaker
- One or more phases of the main AC power supply to the KPP/KSP drive is absent or incorrect.
- Improper connection of three-phase power.
- Blown fuse or tripped breaker on the input power line.
- Internal fault in the KPP/KSP power input stage.
- Voltage imbalance between the phases.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check the power lead connected to the KPP for disconnections or physical damage.
- 2
Inspect the KPP cabling for loose or damaged connections to the mains supply terminals.
- 3
Reinitialize the drive bus by performing a Power Off / Power On cycle of the entire system.
- 4
Check the KPP module itself for internal faults if mains supply is verified correct.