LsrProgramCan- cel
Laser program was canceled
Kuka · LaserTech 3.1
Hva betyr LsrProgramCan- cel ?
The active laser program has been canceled. This can occur if the signal LSRO_LsrReset is set during an active program, or if the signal LSRO_LsrStartStatic is reset before LSRO_LsrStopProgram has been set.
Vanlige årsaker
- The laser program that was active has been canceled.
- Manual intervention canceled the laser process.
- An error condition triggered an automatic cancellation of the laser program.
- Timeout or completion of a programmed laser sequence.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify the state of the LSRO_LsrReset signal during program execution to ensure it is not unintentionally set.
- 2
Check the sequence and timing of LSRO_LsrStartStatic and LSRO_LsrStopProgram signals in the robot program logic.