Oversetter...
F028

Autotuning fault

Schindler · Easy Altivar ATV310 Drive

Hva betyr F028 ?

This ATV310 fault occurs when the drive's auto-tuning function fails to complete successfully. This can be caused by the motor not being properly connected, a motor phase loss during the tuning process, using a special motor type incompatible with standard autotuning, or the motor rotating during the tuning procedure.

Vanlige årsaker

  • Motor is not connected to the drive output during the autotuning process
  • Motor phase loss detected during the autotuning procedure
  • Special motor type that is not compatible with the drive's standard autotuning algorithm
  • Motor is rotating (e.g., being driven by the load) when autotuning is initiated

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check that the motor and drive are compatible for autotuning, referring to documentation.

  2. 2

    Verify that the motor is physically connected to the drive's output terminals during the autotuning process.

  3. 3

    If an output contactor is being used downstream of the drive, ensure it is closed and energized during auto-tuning.

  4. 4

    Check that the motor is completely stopped and uncoupled from the load, if possible, before initiating autotuning.

Se alle koder i denne manualen (37)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Schindler Easy Altivar ATV310 Drive