SEW Eurodrive · MOVIMOT MM..D With AC Motor DRS

Hva betyr 01 ?

An overcurrent condition has been detected in the inverter's output stage, often due to a short circuit. This can occur either within the inverter output itself, the connecting cable to the motor, or the motor windings.

Vanlige årsaker

  • Short circuit on inverter output
  • Short circuit in the connection between inverter output and motor
  • Short circuit in the motor winding

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check the connection between the inverter output and the motor for short circuits

  2. 2

    Check the motor winding for short circuits

  3. 3

    Reset the error by switching off the DC 24 V supply voltage

  4. 4

    Reset the error via the control system or dedicated reset function