97
Copy error (Parameter transmission error)
SEW Eurodrive · MOVIMOT MM..D With AC Motor DRS
Hva betyr 97 ?
An error occurred during the copying process of parameters (also referred to as parameter transmission error), potentially due to interruption of the connection or power supply during data transfer from a keypad or PC.
Vanlige årsaker
- Disconnecting the DBG keypad or the PC during the parameter copying process
- Switching the 24 V supply voltage off and on during the parameter copying process
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Load the factory setting from the DBG keypad or MOVITOOLS® MotionStudio software before acknowledging the error
- 2
Load the complete data record from the DBG keypad or MOVITOOLS® MotionStudio software before acknowledging the error