F10
IPOS-ILLOP
SEW Eurodrive · MOVITRAC 07B System
Hva betyr F10 ?
A stop with inhibit occurs during IPOS program execution. This indicates a wrong command, incorrect conditions, or an unsupported function within the inverter's IPOS environment, leading to a program execution error.
Vanlige årsaker
- Wrong command during IPOS program execution
- Incorrect conditions during IPOS program execution
- Function does not exist or is not implemented in the inverter
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check the IPOS program for incorrect commands
- 2
Check the program run for incorrect conditions or logic
- 3
Use an alternative function if the current one is not implemented in the inverter
Verifisert teknisk data. Sist oppdatert: March 2026