F11

Overtemperature

SEW Eurodrive · MOVITRAC 07B System

Hva betyr F11 ?

A stop with inhibit indicates thermal overload of the inverter. If a braking resistor is integrated in the heat sink, this could exacerbate the issue by generating additional heat.

Vanlige årsaker

  • Thermal overload of inverter
  • Braking resistor integrated in heat sink contributing to heat buildup

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Reduce the load on the inverter to decrease thermal stress

  2. 2

    Ensure adequate cooling by checking ambient conditions and ventilation clearances around the unit

  3. 3

    If a braking resistor is integrated in the heat sink, consider installing it externally to reduce thermal load on the inverter